3-8 Chapter 3
GSE Scale Systems
appear as the name of the referenced parameter. Examples of setup
parameters requiring operating parameter entries are select modes
(P300), database columns (P701) and setpoint comparison parameters
(P5150).
P515)
To change an operating parameter, key in the desired parameter number
and instance (if required) and press [ENTER]. For example, selecting
P5150 and keying in
1.3 å
will enter the net weight of scale 2 as the setpoint compare parameter. If
you forget to enter a required instance, the display will prompt you to enter
one.
If you do not know the number of the parameter you wish to specify, you
can press [ENTER] to display the
the "Gross" parameter. Pressing the up/down arrow keys will scroll
forwards and backwards through all parameters. Press [ENTER] again to
choose the displayed parameter and enter the instance if prompted.
Clearing an Operating Parameter
If you wish to clear an operating parameter rather than enter a new one,
key in 99 [ENTER] as the operating parameter selection. The display will
None!
show
as the operating parameter name. Note that some setup
parameters such as the setpoint compare parameter (P5150) require you
to specify an operating parameter before allowing you to exit the setup
mode. If you have not entered a required operating parameter before
exiting, the display will revert to the offending parameter and allow you to
enter one.
Viewing an Operating Parameter's Number & Instance
When viewing an operating parameter entry, all you see is the parameter
name. You can toggle the display to show the parameter's number and
instance by pressing [F2] on a 660 Series Controller, [TARGET] on a 465
or [UNITS] on a 460.
E
P
XITING THE
ARAMETER
You can exit the setup mode from any parameter by pressing [ZERO] to
initiate the exit routine. When exiting you are given the opportunity to
calibrate and save or undo all changes you made while in the setup mode.
CmPar
Gross
Pick Parm:
list. The list starts with
S
M
ETUP
ODE