Operating Parameters 7-39
S
= Stable
The transmitted status character(s) can be changed at P143 à P145 in
the setup mode.
When transmitting 97P through a custom transmit, the field width is that of
the largest string assigned at P143 à P147.
When transmitting 97P via Modbus, only the first character of the names
defined at P143 à P147 is transmitted.
D
W
/C
(P
98)
ISPLAYED
EIGHT
OUNT
ARAMETER
The current displayed weight/count parameter is used most commonly in
custom transmit tables to provide and indication of the current gross, net,
tare or quantity value, whichever is currently displayed. If a parameter
other than gross, net, tare or quantity is selected as the current operating
mode, 98P will begin reporting only the gross weight.
E
G
(P
99)
XTENDED
ROSS
ARAMETER
The extended gross parameter is used to momentarily display the current
gross weight at 10X the selected division size. This is useful when
verifying calibration to determine how close the gross weight is to the next
weight division.
60 Series Technical Reference Manual