3-40 Chapter 3
GSE Scale Systems
P856: Maximum Expected Frequency
Assigns the maximum expected frequency when P851 is set for frequency
debounce.
P857: Clock Source
Selects clock source A (65,536 Hz) or clock source B (524,288 Hz). A
higher clock speed will provide more accuracy for some functions but
could also shorten the duration of the measurement period for others.
P858: Pulse Edge Detection
Selects either a rising or falling edge as the reference for determining
pulse count and frequency.
P859: Pulse Measurement Period
Assigns the time period in milliseconds for determining the frequency
when P851 is set for Frequency Input A.
P860: Number of Pulses to Measure
Assigns the number of pulses to measure for determining the frequency
when P851 is set for Frequency Input B.
P861: Phase Measurement Type
Selects whether to monitor Low time or High time for determining the duty
cycle when P851 is set for Phase Time.
P862: Pulse Type
Permanently set for sink when P851 is set for Delay Output.
P863: Pulse Scaling Factor
Assigns a variable to be used as the pulse input scaling factor. If a
variable is not assigned to P863, the scaling factor will be 1:1 (each pulse
will be counted and displayed).
If a variable is assigned, then the variable's value is used as a conversion
factor for displaying received pulses. For example, a scaling factor of 0.1
will display one pulse for every 10 pulses received.
P864: Number of Decimal Places
Selects the number of decimal places to use when displaying a pulse
count with a scaling factor.
C
T
USTOM
RANSMIT
The custom transmit parameters provide configuration of the custom
transmit tables and the criteria for transmission.
P980: Continuous Transmit Rate
Assigns the interval to a resolution of 0.1 seconds at which continuous
transmits are transmitted.