6. Install the load cell leads into J2 on the main board (see Figure 2-9
and refer to page 2-19).
To close the 663 Controller:
1. Move the rear cover into position. Ensure that all of the cables are
positioned within the cutouts of the cover. Press the cover straight
towards the panel until the left and right side slots snap over the tabs
on the mounting plate.
2. Mount the rear cover, if used, to the controller with the four 8-mm hex
head screws.
3. Install the M4 hex bolt in the upper left corner using a 7mm socket.
4. Reconnect any cables from the respective source connectors.
5. Close the controller enclosure door.
6. Slide the exterior door fastening clamps to the left (see Figure 2-11).
7. Using a large, flat-tip screwdriver, tighten the 1/4-20 slotted pan head
screws on the fastening clamps.
8. Connect the controller to an AC power supply to power it on.