D
V
ECIMAL
ALUE
(C
C
)
ONTROL
ODE
LCD Control Codes (Character Set)
000 à 181
Transmit standard LCD characters (Comm Port 5; refer to LCD character set)
800 à 866
Transmit custom LCD characters (Comm Port 5 only; refer to LCD character set)
4X20 VFD Control Codes (Custom Display Commands)
008
Move cursor left one space
009
Move cursor right one space
010
Move cursor down one row
012
Move cursor to top left corner (home)
013
Move cursor to beginning of line
014
Clear entire display
017
Scroll mode OFF
018
Scroll mode ON
020
Cursor OFF
021
Cursor ON
024
Set INTERNATIONAL character set
025
Set KATAKANA character set
027, 067
Define custom character
027, 072
Position cursor at specified location
027, 073
Reset display default values
027, 076
Set display intensity
027, 084
Set cursor blink speed
4X20 VFD Control Codes (Character Set)
032 à 213
Transmit standard VFD characters (Comm Port 5; refer to LCD character set)
Combination ASCII Control Codes
256
Insert both carriage return and line feed <CR> <LF>
Checksum Control Codes
300
Stop checksum calculation (do not transmit)
301
Start CCITT checksum calculation
302
Start SDLC/HDLC checksum calculation
303
Start CRC-16 checksum calculation (initial checksum value = 0000)
304
Start CRC-12 checksum calculation
305
Start LRCC-16 checksum calculation
306
Start LRCC-8 checksum calculation
307
Start XMODEM checksum calculation
308
Start SUM-16 checksum calculation
309
Start SUM-8 checksum calculation
will enter the <CR><LF> combination.
Any other ASCII character, including printable characters, may be entered
using this method. Referencing the ASCII chart in Appendix B, 'GSE'
could have been entered as:
.071 [ENTER]
G
.083 [ENTER]
S
.069 [ENTER]
E
C
GSE C
USTOM
When communicating with the LCD or 4X20 VF displays, many of the
standard ASCII control codes are used to perform specific functions or
display custom characters. Additionally, many custom control codes were
created to transmit other status information. Refer to Table 8-5 for a
complete list of these codes. All custom control codes are entered in the
same manner as standard control codes using the three-digit ASCII value
preceded by a decimal '.'.
Table 8-5: Custom GSE Control Codes
D
ESCRIPTION
Backspace
Horizontal Tab
Line Feed
Form Feed
Carriage Return
Shift Out
Device Control 1
Device Control 2
Device Control 4
Negative Acknowledge
Cancel
End of Medium
Escape + C
Escape + H
Escape + I
Escape + L
Escape + T
C
ONTROL
ODES
<BS>
<HT>
<LF>
<FF>
<CR>
<SO>
<DC1>
<DC2>
<DC4>
<NAK>
<CAN>
<EM>
<ESC> + 'C'
<ESC> + 'H'
<ESC> + 'I'
<ESC> + 'L'
<ESC> + 'T'
60 Series Technical Reference Manual
Communications 8-15
R
EFERENCE
C-1
13-60
C-1
8-22
8-41