ribbon cable into the connector labeled 'NEXT' on the installed
module.
4. Install the 2-Option mounting plate onto the RF cover using the M5
Philips screw and M5 hex nut.
5. Align the slots on the mounting plate with the two holes in the RF
Cover.
6. Insert the screws though the holes so the heads of the screws are on
the mounting plate and the screw threads protrude into the inside of
the RF cover.
7. Tighten the nuts onto the screw threads to hold the mounting plate in
place.
8. Install the 4 aluminum standoffs included in each 60 Series Option Kit
onto the studs on the mounting plate. See Figure 13-6.
9. Tighten the standoffs hand tight. Do not over torque!
10. Place the module over the threaded standoffs.
11. Install the 4 5.5mm hex nuts on the standoffs to secure the module.
12. Connect the ribbon cable from the main board to J1 on the module.
Figure 13-6: Installing an SBM on a Two-Option Mounting Plate
The second module installs in the same manner with the ribbon cable
connected between the first module's 'NEXT' connector and the second
module's 'MAIN' connector. Figure 13-7 shows two serial I/O modules
installed on the RF cover.
60 Series Technical Reference Manual