GSE 60 SERIES Technical Reference Manual page 319

Programmable process controllers
Table of Contents

Advertisement

< transmit# > [ . comm ] %Q
Enable / Disable Continuous Transmit
< transmit# > [ . comm ] [C | D] %Q
Set Continuous Transmit Interval
< seconds > I%Q
Set Continuous Transmit Interval to Display Rate
< transmit# > [ . comm ] X%Q
If Custom Transmit Continuous
< transmit# > [ . comm ] ?%Q
Arguments
C
Send custom transmit continuos.
D
Cancel continuous custom transmit.
X
Send custom transmit at display rate while in net or gross
mode.
Custom transmit (1 à 250) to send.
transmit#
Communication port (1 à 4).
comm
Number of seconds (0.01 à 2,883,584) to delay between
seconds
continuous transmits.
Notes
The seconds argument does not change the setup mode
selection at P980, rather it temporarily changes the
continuous transmit interval until power is interrupted or
upon saving changes when exiting the setup mode.
Only one custom transmit is allowed to be transmitted at
the display rate any new #X%Q will replace the previous.
0X%Q or X%Q will stop this custom transmit.
See Also
%p
Print
Send Custom Transmit
< transmit# > [ . comm ] %Q
Initiates the transmission of a specified custom transmit. The %Q
command will send a custom transmit regardless of the send criteria at
P991 (even if set to 'Off'). The transmission will occur out the comm port
specified at P992 unless a different port is specified with the comm
argument. Motion delay criteria at P993 à P997 will be enforced and
macro will be suspended for the duration of any motion delay.
1%Q
Sends custom transmit 1 out the comm port specified at
P992.
2.3%Q
Sends custom transmit 2 out comm 3.
60 Series Technical Reference Manual
Macros 9-71