7-38 Chapter 7
GSE Scale Systems
A
'L
' P
SSIGNING
IVE
D
ISPLAY
To allow displaying live operating parameters in the seven segment area
at the same time as user supplied data is shown in the dot matrix area of
the display, a weigh mode parameter (0P – 98P) can be displayed on the
seven-segment portion of the display.
In order to cause a weigh mode parameter to be continuously updated on
the numeric portion of the display, the instance specified for 90P must be
'12'. For example,
91.12P="0.0P"%o
The quotes are required, otherwise you will get only a static snapshot of
the parameter. The following are equivalent:
91.12P=0.0P%o
91.11P=0.0P%o
!
Note the missing quotes! It is also important to realize that adding
quotes has different effect for instances 11 & 12 of parameter 91.
G
D
ET
ISPLAYED
Parameter 92 is used to return the string data from either the 2x5
character portion or the numeric portion of the display. This data is placed
in the entry buffer.
place 2x5 character data in entry buffer
92.0P%o
92.10P%o place numeric data in entry buffer
This parameter not directly accessible from the keypad, nor is it usable in
input interpreters, or at p300 à 309. Data can only be retrieved to the
entry buffer.
D
IAGNOSTIC
The diagnostic weight parameters are used to report information about the
displayed weight parameters.
S
(P
TATUS
ARAMETER
The status parameter is used in custom transmits to indicate the status
(motion, stable, over/under load) of each scale. By default, the status
characters transmitted are:
O = Overload/Underload
M = Motion
ARAMETERS TO THE
D
(M
92)
ATA
ODE
W
P
EIGHT
ARAMETERS
97)
N
UMERIC