GSE 60 SERIES Technical Reference Manual page 128

Programmable process controllers
Table of Contents

Advertisement

5-16 Chapter 5
GSE Scale Systems
3. Press the [ENTER] key. The controller tares to a zero net weight. The
display shows the current net weight and prompts, Add 10 (the actual
number can be programmed by setup parameter P182).
4. Place the specified number of parts on the scale.
5. Press [ENTER]. (Or add any number of parts, key in the number
added, then press [ENTER].) The controller calculates the piece
weight of the sample parts. If the number of parts added was
insufficient to achieve the required accuracy as set by P183, then you
are prompted to add an more parts.
6. Add the specified number of parts and press [ENTER].
7. Add the additional parts to be counted on the scale.
Method 2: Counting with piece weight enhancement
1. Access the quantity mode.
2. Place empty container on platform (optional).
3. Press the [ENTER] key. The controller tares to a zero net weight. The
display shows the current net weight and prompts: Add 10 (the actual
number can be programmed in setup parameter P182).
4. Place the specified number of parts on the scale.
5. Press [ENTER].
6. The controller calculates the piece weight of the sample parts and
momentarily displays the maximum number of parts that can be added
for a piece weight enhancement to occur. Then it displays the
minimum achieved accuracy.
7. If a greater accuracy is desired, add more parts but not more than the
maximum enhancing quantity.
8. As soon as motion ceases, the controller recalculates the piece weight
and briefly displays the new maximum number of pieces that can be
added and still accurately enhance the piece weight.
9. Repeat as many times as desired.
10. Add the additional parts to be counted.
Method 3: Counting with a known container weight
1. Access the quantity mode.
2. Place the full container of parts on the weigh platform.
3. Press the [ENTER] key.
The controller tares to a zero net weight. The display shows the
current net weight and prompts, Add 10. (Add means take in this
instance). The actual number can be programmed in setup parameter
P182).
4. Remove the specified number of parts from the box.
5. Press [ENTER].