GSE 60 SERIES Technical Reference Manual page 369

Programmable process controllers
Table of Contents

Advertisement

Exit Macro Menu
*%s
Exits the macro menu without invoking a macro. This can also be
accomplished with the %i or %z command.
T
%t
ARE
Syntax
Tare
[ value ] %t
Arguments
value
Tare weight value.
scale#
Select from the following scale numbers:
0
Current scale
1
2
3
4
5
6
7
8
Notes
Specifying a tare value sets the preset flag for the tare
weight.
See Also
%z
Zero
%`
Scale Select
%-
Perform Scale Specific Function
Tare
[ value ] %t
Establishes a new tare weight for the current scale.
%t
Performs a motion delayed auto-tare (tare = gross).
10%t
Simulates a manual tare entry (tare = 10).
0%t
Clears the tare weight (tare = 0).
A tare command must originate from the gross, net, tare, or any of the
accumulation parameters (parameters 0P à 9P). If NTEP is disabled in
the setup mode at P440, then the net mode is automatically selected after
performing a tare (with the exception of performing a tare from the tare
mode). If NTEP is enabled, the net mode is not automatically selected if
the gross weight is zero.
Scale 1
Scale 2
Scale 3
Scale 4
Scale 5
Scale 6
Scale 7
Scale 8
60 Series Technical Reference Manual
Macros 9-121