Input Specification Macro Number; Clear Interpreter - GSE 60 SERIES Technical Reference Manual

Programmable process controllers
Table of Contents

Advertisement

parameter, and a lowercase
keys perform special functions:
[F3ƒ]
Moves the edit position left.
[F5„]
Moves the edit position right.
[F4‚]
Expands character at edit position.
[F1‚]
Enters Alphanumeric entry mode.
[ENTER]
With no entry, enters the parameter select mode.
Following an entry, inserts entry into format line at edit
position.
[CLR] With edit position at the end of the format line will ask if you want
to delete the entire line by prompting "Clear All?"; press [ENTER]
for "yes," any other key for "no." Otherwise, it deletes the character
at the edit position
In the Alphanumeric entry mode, [F1•] and [F4‚] are used to scroll up
and down through the ASCII character set. [F3ƒ] acts as a backspace,
removing the character at the edit position and moving the edit position to
the left by one character. The [F5„] key moves the edit position one
character to the right and places an "A" there.
In the parameter select mode, [F1•] and [F4‚] are used to scroll up and
down through the available parameters. The parameter number is
displayed in the last two digits of the numeric display. If you know the
parameter number, you can enter it directly. When the name of the
parameter you want is displayed, pressing [ENTER] will insert it into the
format line at the edit position.
Control codes are inserted by entering ".XXX" when XXX is the decimal
code for the control code. For example, keying in [•] 013 [ENTER] inserts
a carriage return at the edit position.
Use caution when entering a "%" in the format line. In order to match a "%"
in the received data, the format line must contain two percent signs, or
"%%." To enter two percent signs in the setup mode requires that four
percent signs be sent to the scale. A single percent sign has a special
meaning for the input interpreter, which is described in the For
Programmers Only section in this Chapter.
I
S
NPUT
PECIFICATION
The macro number is programmed at Parameter P224. Here you select
the number of the macro you want to initiate when a match is found. The
choices are 1 through 250 (macro number), 0 = none. Key in the number
of your selection and press [ENTER] to select a specific selection, or
press [ENTER] by itself to scroll through the selections.
C
I
LEAR
NTERPRETER
Specify the interpretation number in question at P219. Press [n] [ENTER]
to review a specific interpreter (n = 1 through 250). Press [CLR] to delete
an interpreter specification. A prompt will read "Clear One?". Press
[ENTER] to verify clear. To clear all key in [999] [ENTER] at this prompt.
Communications 8-43
C
indicates a control code. Here the following
C
M
N
ACRO
UMBER
60 Series Technical Reference Manual