Operating Parameters 7-25
number may not be seen unless you read the A/D conversion number
immediately after setting it.
U
W
C
T
SING
ITH
USTOM
RANSMITS
The A/D conversion number parameter was created primarily for use with
custom transmits (P1000). The same custom transmit must contain 63P
and the desired parameters for which the corresponding A/D conversion
number is desired. To send a continuous transmit at high rates (60 Hz
maximum) the baud rate (P200) must be fast enough, the scale filter
settings at P116 must be fast enough and the amount of data sent by the
custom transmit must be limited. Finally, P980, TxRate only allows
multiples of 0.1 second. To change the transmit rate to alternate multiples
the I%Q macro must be used. It is important to realize that this rate will be
reset to the value at P980 on power up and when exiting setup mode!
Example
th
To send a continuous transmit every 30
of a second out comm port 1,
first set the filter at P116 for the scale you are interested in to 1.0 second.
Set P998 (Continuous Transmit) to "enabled" and configure the custom
transmit table as desired (use 63P). After saving and exiting setup mode
or after powering up, send a .033I%Q to override the interval at P980. It
important to note that setpoints, programmable IO operations, macros, and
use of other comm ports will affect the transmission rate.
DSD P
ARAMETERS
The Data Storage Device (DSD) parameters are associated only with the
DSD feature. DSD must be enabled at P590 and configured at P591 à
P595 in order to use these parameters.
DSD P
(P
64.1 – 64.9)
ARAMETERS
ARAMETERS
Refer to the DSD database structure on page 6-14 for a complete
description of DSD parameters.
S
T
ETPOINT
IMERS
The setpoint timer parameters are used to display or manipulate the 256
independent setpoint delay timers. These parameters are not displayable
modes of operation, but can be used in custom transmit tables or macros
to display or change timer values.
60 Series Technical Reference Manual