GSE 60 SERIES Technical Reference Manual page 320

Programmable process controllers
Table of Contents

Advertisement

9-72 Chapter 9
GSE Scale Systems
Enable / Disable Continuous Transmit
< transmit# > [ . comm ] [C | D] %Q
Allows any custom transmit to be transmitted on a continuous basis.
Enabling or disabling a continuous transmit with the %Q command will
override the continuous transmit selection at P998. The transmission will
occur out the comm port specified at P992 unless a different port is
specified with the comm argument. Motion delay criteria at P993 à P997
will be enforced but will not suspend macro execution during a motion
delay.
As many as 16 custom transmits may be set for continuous transmission.
An attempt to send more than 16 continuous transmits will be disregarded
Code72 ConTx >Max!
and result in a
specify a continuous transmit that is already continuous at the specified
comm port will result in a
The interval at which the continuous transmit list will be sent is based on
the interval specified at P980. This interval can be overridden with the
I%Q command.
Continuous transmits are sent in the order in which they were added to the
continuous transmit list. For example, if custom transmit 3 is specified as
continuous prior to custom transmit 1, then custom transmit 3 will be sent
before custom transmit 1 at the beginning of each custom transmit interval.
A custom transmit set for continuous transmission that is set for motion
delay at P993 à P997 will be skipped if the motion criteria exists at the
time of the next custom transmit interval. Continuous transmits are not
sent if the transmit buffer of the intended port is not empty. This prevents
a backlog of transmission data. If the size of a transmission exceeds the
transmit buffer size, the weight conversion process may become delayed
by the transmission. Make sure the transmit buffer size at P207 is large
enough to accommodate the largest transmission.
1C%Q
Sends custom transmit 1 continuously out the comm
port specified at P992.
2.3C%Q
Sends custom transmit 2 out comm port 3
continuously.
2D%Q
Cancels the continuous transmission of custom
transmit 2 out the comm port specified at P992.
2.3D%Q
Cancels the continuous transmission of custom
transmit 2 out comm port 3.
D%Q
Cancels all continuous transmissions.
Set Continuous Transmit Interval to Display Rate
< transmit# > [ . comm ] [X] %Q
error message. Attempting to
Code75 Tx is Cont.
error message.