Operator Access To Time/Date; Time/Date Transmit Code (Formats); Time And Date Parameter Setup; Time/Date Specifications - GSE 60 SERIES Technical Reference Manual

Programmable process controllers
Table of Contents

Advertisement

5-8 Chapter 5
GSE Scale Systems
O
A
PERATOR
CCESS
You can access and change the time and date directly from the weigh
mode by selecting parameter 11. If P502 is set for "Enbld" (changeable),
then you will be allowed to change the time when you select parameter 11.
This allows end users to adjust the time without having to know the setup
access code for the controller. If Parameter P502 is set for "Disbl", then
the time/date can only be changed by accessing the setup mode at P500
and P501.
T
/D
T
IME
ATE
RANSMIT
Format code combinations are included in the time/date format selections
for transmitting the T/D parameter from a custom transmit table or a
macro. These format codes allow a time/date type variable (current time,
or variables defined as U-INTs) to be transmitted as a numeric value in
terms of the number of seconds elapsed since Jan 1, 1970. This is useful
in uploading time/date information to a computer for spreadsheet
applications. Refer to Chapter 8, Communications for more information on
time/date transmitting (multiple formats).
T
A
D
IME
ND
ATE
Time and date setup parameters begin at P500 à P504. Refer to page 3-
37 for complete details.
The default name used when transmitting the time & date parameter can
be changed in the setup mode at P611 (see page 3-38).
T
/D
S
IME
ATE
PECIFICATIONS
The 60 Series battery-backed time/date module is a continuously running
clock, even when the indicator is powered down. The time and date is set
(as Eastern Standard Time) at the factory prior to shipment. See page A-
16 for complete specifications.
T
/ D
O
IME
ATE
PERATION
Apply power to the controller and verify proper operation. To verify the
time and date values, select the time/date mode. Key in 11 [SELECT]
The display will show the date on the large numeric digits and the time on
the dot matrix display. For example, for July 16, 1996 at 3:27:23 p.m., the
display will appear as 07.16.96 03:27:23pm.
Refer to the P500 setup parameters to enter the time and date or to
change the format of the time and date. To include the current time and /
or date into the data transmissions to a printer or other peripheral, refer to
the Custom Transmit (Selections) Parameter Setup section Chapter 8,
Communications, Chapter 9, Macros, and Chapter 10, Setpoints for
examples on setting up alarm routines (alarm routines configured using
macros and setpoints).
T
T
/D
O
IME
ATE
C
(F
ODE
ORMATS
P
S
ARAMETER
ETUP
)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents