The parameter renaming parameters provide the ability to rename various
operating parameters.
P600 – P646: Rename Parameters
Assigns alternate names to operating parameters. Assigned names are
displayed and transmitted in place of the default names. This feature is
useful when configuring the indicator for foreign languages.
Note that counting must be enabled at P179 in order for the counting
rename parameters to become available.
T
& T
S
OTAL
ARE
AVE
The total & tare save parameters are used to enable the tare and
accumulation parameter values to be saved in non-volatile memory and
restored in the even of power loss.
P660 – P661: Total / Tare Save Method
Selects whether accumulation values and tare values will be written to the
EEPROM each time the values change so that the values may be retained
and restored in the event of a power loss.
If set to AUTO, the values are automatically stored to the EEPROM when
changed.
If set to No Save, the values are not written to the EEPROM and will be
lost during a power failure.
If set to On Request, the values can only be written to the EEPROM via
the %v macro command.
V
ARIABLES
The variable parameters allow configuration of variables.
P680: Number of Variables
Assigns the number of variable registers to be dynamically allocated.
Once allocated, the number of variables may be increased or decreased
as necessary (memory permitting).
P681: Variable Instance
Sets the variable# in effect when accessing the remainder of the variable
configuration parameters P682 à P689.
P682: Variable Name
Assigns a name to the variable for documentation and display purposes.
To display the name of a string variable or scale-specific float variable, the
name must be 5 characters or less. If the name is greater than 5
characters, the default variable name (V#xxx) will be displayed. However,
the entire given name will still be transmitted.
To display the name of a all other variables, the name must be 10
characters or less. If the name is greater than 10 characters, the default
Setup Parameters 3-37