9-124 Chapter 9
GSE Scale Systems
with the %R command to display a bag count on the 2X5 prompting
display during a filling cycle.
0,LB%u
Renames "lb" to display "LB" when pounds is selected.
3,Count%
Renames "g" to display "Count" when grams is selected.
u
6,Liter%u
Renames custom unit #1 to display "Liter" when selected.
W
V
%v
RITE
ALUE TO
Syntax
Write Value to EEPROM
80. < variable# > %v
Arguments
variable#
Valid variable number to store in non-volatile memory.
Notes
A variable must be set for "OnReq" (on request) at P684
to utilize the %v command.
See Also
%o
Math Assignment
Write Value to EEPROM
Stores the current value of a specified variable to non-volatile to the
EEPROM. The stored value will then be retained while the indicator is
powered down and be restored upon power-up. Note that the value
restored at power-up will be the last value stored using the %v command.
If the variable's value was changed thereafter, the new value is not stored.
80.1%v
Stores the value of VAR#1 to non-volatile EEPROM.
80.5%v
Stores the value of VAR#5 to non-volatile EEPROM.
Use the %v command should be used instead of the "Auto" save selection
at P684 whenever practical. This reduces the number of writes to
EEPROM which has a suggested life expectancy of 100,000 writes.
EEPROM