19.12.2
Signals to axis/spindle (DB31, ...)
DB31, ...
DBB0
Feed rate override (axisspecific)
Edge evaluation: No
Signal state 1 or
The axisspecific feed rate override can be defined via the PLC in binary or Gray coding. With binary
edge change
coding, the feed value is interpreted in %. 0% to 200% feed changes are possible, in accordance
0 → 1
with the binary value in the byte.
The following permanent assignment applies:
Binary values > 200 are limited to 200%.
Using the machine data:
MD12100 $MN_OVR_FACTOR_LIMIT_BIN (limit for binary-coded override switch)
the maximum axis-specific feed rate override can be additionally limited.
In gray coding, the following codes are assigned to the individual switch settings:
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Signal(s) updated: Cyclically
Z1: NC/PLC interface signals
19.12 Feeds (V1)
1727