12.3 Reading in / reading out PLC projects

12.3
Reading in / reading out PLC projects
When reading in a project, this will be transferred to the file system of the PLC and then
activated. To complete the activation, the control system is restarted (warm start).
Reading in project from CompactFlash card/USB FlashDrive
To read in a PLC project, perform the following operator actions:
1. CompactFlash card/USB FlashDrive are inserted
2. Press the "Customer CF card"/"USB drive" softkey and select the line with the desired
3. Press "Copy" to copy the file to the clipboard.
4. Press the "802D data" softkey and position the cursor on the PLC Project (PT802D
5. Press the "Paste" softkey; reading in and activation starts.
Writing project to CompactFlash card/USB FlashDrive
Perform the following operator actions:
1. CompactFlash card/USB FlashDrive are inserted
2. Select the "802D data" softkey and position the direction keys on the PLC project
3. Press "Copy" to copy the file to the clipboard.
4. Press the "Customer CF card"/"USB drive" softkey and select the saving location for the
5. Press the "Paste" softkey; the writing process starts.
12.4

Copying and pasting files

In the <PROGRAM MANAGER> operating area and in the "Start-up files" function, files or
directories can be copied into another directory or onto a different drive using the softkey
functions "Copy" and "Paste". When doing so, the "Copy" function enters the references to
the files or directories in a list which is subsequently executed by the "Paste" function. This
function will perform the actual copying process.
The list is kept until a new copying process overwrites this list.
Special situation:
If the RS232 interface has been selected as the data target, "Paste" will be replaced by the
"Send" softkey function.. When reading in files ("Receive" softkey), it is not necessary to
specify a target, since the name of the target directory is not contained in the data flow.