4.7
Program setting data
Functionality
The setting data are used to define the settings for the operating states. These can be
changed as necessary.
Operating sequence
You are now in the <OFFSET PARAM> operating area.
Press the "Setting data" softkey. The start screen "Setting data" is opened. Other softkey
functions are available here with which you can set various control system options.
Figure 4-23
● JOG feedrate
● Spindle
● Minimum / maximum
● Limitation using G96
Surface grinding
Programming and Operating Manual, 11/2012, 6FC5398-5CP10-3BA0
Setting data start screen
Feedrate value in JOG mode
If the feedrate value is zero, the control system will use the value stored in the machine
data.
Spindle speed
A limitation of the spindle speed in the "Max." (G26) / "Min." (G25) fields can only be
performed within the limit values defined in the machine data.
Programmable upper speed limitation (LIMS) at constant cutting rate (G96).
Setup
4.7 Program setting data
49