Reading Out The Datalog File - Siemens SIMATIC S7-1200 Manual

Hide thumbs Also See for SIMATIC S7-1200:
Table of Contents

Advertisement

7 Operating the Application
7.3 Live demo
7. Via this button you get to the web server of the S7-1200 controller (only
possible for real Comfort Panel).
8. Via this button you get to the time setting of the S7-1200 controller.
7.3.5

Reading out the DataLog file

You have the option to read out the csv file with the recorded process data via the
Internet Explorer in Windows CE on your Comfort Panel or via an Internet Browser
on your programming device.
Proceed as follows:
Table 7-5
No.
1.
Start the Internet Explorer.
As address, enter the IP address of the
CPU:
http://192.168.0.1
here:
Click on "ENTER".
2.
You get to the start page. Here, you have
the option to logon to the web server with
the access data previously determined in
the user administration in order to receive
certain authorizations. In the example
project the administrative access level for
all users was created.
Open the file browser.
Open the "DataLogs" folder in the file
browser.
3.
As a result, the list with all available
DataLog files opens, including file size
specification and system time stamp of the
last access.
You also have the option here to delete the
DataLog files or to rename them.
They have to be closed to be able to do
this.
Click on the name of the "DataLog.csv"
file.