Row Usage Report - Teledyne Kibra DDR User Manual

Protocol analyzer suite
Table of Contents

Advertisement

Teledyne LeCroy
3.9

Row Usage Report

 
To run the Row Usage Report select Analysis > Row Usage Report from the menu to 
display the following dialog. The Row Usage Report allows the user to define commands 
of interest within a row, sets of rows or the entire captured trace. The user can then 
define a reset to a cycle. The Report tallies the number of commands defined within each 
cycle with minimum, maximum and average per selected row. This is useful when trying 
to determine the min/max and average write command to an activated row. The user 
defines the rows desired, selects the Write Command, and resets on PRE/PREA. This 
generates a report showing the min/max and average number of writes per activate for 
the desired row or rows. The user should count the number of cycles or time the row was 
activated for a Write command. Another use of the report would be for determining 
"Row Hammering". The user defines the desired rows, the Activate command and the 
reset or cycle as a Refresh command. This allows the user to determine the number of 
activates to an aggressor row as well as a victim row before either were refreshed.
Run Analysis button
Figure 3.62: Row Usage Report Dialog
Click the Run Analysis button (see figure above) to display the Row Usage Analysis dialog 
(see Figure 3.63 on page 145).
144
 
Report filters
K ibra DDR Protocol Analyzer User Manual
 
 Row Usage Report

Advertisement

Table of Contents
loading

Table of Contents