Teledyne LeCroy
Figure 2.63: Row Usage Report Dialog
2.21
Timing Violation Analysis
The Timing Violation Analysis dialog (see Figure 2.64 on page 91and Figure 2.65 on
page 92)displays the memory controller and timing violation parameters. Refer to
"Recording Options ‐ Basic Settings Tab" on page 42 for more information.
This allows the user to run the Violation Check on the trace data with revised values for
the timing parameters. You can do "What if?" scenarios to see if the new values would
have created violations had they been in place during the capture. The default for Follow
MRS Settings is OFF in this feature, Please ensure it is turned on if you want the software
to follow the MRS changes as it analyzes the trace. But in that case, be aware that the
values you changed may be overridden by values obtained from the MRS commands.If
the trace was captured with no filtering, a checkbox is provided to allow the user to
change the CAL value.
90
Timing Violation Analysis
K ibra DDR Protocol Analyzer User Manual