Command Filter Out - Teledyne Kibra DDR User Manual

Protocol analyzer suite
Table of Contents

Advertisement

Recording Options Setup
When a device is connected, click on the double‐arrow icon 
DIMM speed of the device. The application automatically inspects the device and displays 
its speed, as long as the Host Under Test (HUT) is active.
If users select combinations in the Memory Controller settings which are not specified by 
JEDEC specification for the appropriate Speed Bin, the application will display an error in 
Red for the CL (nCK) and/or CWL (nCK) values with an exclamation mark (!) (see 
Figure 2.17 on page 51). In this case, the analyzer will not enable the refresh button for 
the timing violation triggers. The software will populate the Timing table with the last 
valid set of timing values. The user may modify the individual timing values manually as 
desired.
Note:
If operating the analyzer with invalid memory controller parameters, the analyzer software will 
capture normally but may flag numerous timing violations.
Figure 2.17: Error in Memory Controller Settings

Command Filter Out

The option is NOP/Deselect. This option allows the customer to filter out the NOP / 
Deselect states. The NO Operation and Deselect are considered idle states and can be 
filtered to allow more commands states to be captured. Idle States will show in the 
WaveForm and Bank State views as Hashed marks vertically through the waveform.
Figure 2.18: Command Filter Out Dialog
       
K ibra DDR Protocol Analyzer User Manual