Error Code Description
4067 0EE1 Bus tests detected fault in service processor
code (invalid MRU to mapping)
4067 0EE2 Bus tests detected fault in service processor
firmware fault
4067 0EE5 Bus tests detected firmware error; no callout
available
4067 25E6 SMA 4-port switch adapter fault
4067 273F SMA 2-port switch adapter fault
4068 0001 Other bus tests detected clock card assembly
failure
4068 0002 Other bus tests detected backplane assembly
failure
4068 0003 Other bus tests detected fault in MCM module
0
4068 0004 Other bus tests detected fault in MCM module
2
4068 0005 Other bus tests detected fault in MCM module
1
4068 0006 Other bus tests detected fault in MCM module
3
4068 0007 Other bus tests detected fault in L3 VPD card
4068 000A Other bus tests detected fault in primary I/O
book 1 (slot 0)
4068 000B Other bus tests detected fault in secondary I/O
book (slot 1)
4068 000C Other bus tests detected fault in I/O book 3
(slot 2)
4068 000D Other bus tests detected fault in I/O book 4
(slot 3)
4068 000E CUoD capacity card
4068 0010 Other bus tests detected fault in Memory book
(slot 0)
4068 0011 Other bus tests detected fault in Memory book
(slot 1)
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
Replace the I/O book (switch adapter) specified
by the location code.
Replace the I/O book (switch adapter) specified
by the location code.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
MCM module 0 and VPD card
Location: U1.18-P1-C1 and U1.18-P1-H2.3
MCM module 2 and VPD card
Location: U1.18-P1-C4 and U1.18-P1-H2.4
MCM module 1 and VPD card
Location: U1.18-P1-C3 and U1.18-P1-H2.5
MCM module 3 and VPD card
Location: U1.18-P1-C2 and U1.18-P1-H2.6
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as "new
defective".)
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
Memory book (slot 0)
Location: U1.18-P1-M2
Memory book (slot 1)
Location: U1.18-P1-M3
Chapter 5. Error Code to FRU Index
571