Chapter 11. SRNs for Linux

The x in the following group of SRNs is encoded as follows:
8 4 2 1
| | | |
| | | Replace all FRUs listed
| | Hot swap supported
| Software might be the cause
Reserved
Note: Some SRNs in this chapter may have 4 rather than 3 digits after the dash (-).
Use the physical location codes and FRU numbers listed on the diagnostics Problem Report
Screen.Failing Function Codes (FFCs) are not used in this group of SRNs. For more detailed information
refer to "MAP 1230: Linux Platform Error Problem Resolution" on page 165.
Description and Action
Service
Request
Number
651-88x
The CEC or SPCN reported an error. Action: Refer to the entry MAP in this system unit's
system service guide, with the 8 digit error and location codes, for the necessary repair
action. If the 8 digit error and location codes were NOT reported, then call support.
651-89x
The CEC or SPCN reported an error. Action: Refer to the entry MAP in this system unit's
system service guide, with the 8 digit error and location codes, for the necessary repair
action. If the 8 digit error and location codes were NOT reported, then call support.
652-88x
The CEC or SPCN reported a non-critical error. Action: Schedule deferred maintenance.
Refer to the entry MAP in this system unit's system service guide, with the 8 digit error and
location codes, for the necessary repair action. If the 8 digit error and location codes were
NOT reported, then call support.
652-89x
The CEC or SPCN reported a non-critical error. Action: Schedule deferred maintenance.
Refer to the entry MAP in this system unit's system service guide, with the 8 digit error and
location codes, for the necessary repair action. If the 8 digit error and location codes were
NOT reported, then call support.
Description: Error log analysis is unable to determine the error. The error log indicates the
following physical FRU locations as the probable causes. Action: Use "MAP 1230: Linux
A00-FF0
Platform Error Problem Resolution" on page 165.
Description: Error log analysis indicates an error detected by the CPU, but the failure could
not be isolated. Action: Use "MAP 1230: Linux Platform Error Problem Resolution" on page
A01-00x
165.
Description: CPU internal error. Action: Use "MAP 1230: Linux Platform Error Problem
Resolution" on page 165.
A01-01x
Description: CPU internal cache or cache controller error. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 165.
A01-02x
Description: External cache parity or multi-bit ECC error. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 165.
A01-03x
Description: External cache ECC single-bit error. Action: Use "MAP 1230: Linux Platform
Error Problem Resolution" on page 165.
A01-04x
Description: System bus time-out error. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 165.
A01-05x
Description: Time-out error waiting for I/O. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 165.
A01-06x