On/off processor day charge
An informational log entry is made when the system decrements the processor day counter at the
start of each 24 hour period (including the first one). The "account" is being charged for the next
day's use of the processor.
v Word 16 value (first 2 bytes): 0800
v Word 17 value (first 2 bytes): The number entered on the processor on/off CoD management
screen on the HMC. This is the number of on/off CoD resources that is being requested.
v Word 17 value (second 2 bytes): The number of on/off CoD resource currently active. It may be
smaller than the number requested due to failing resources.
v Word 18 value (first 2 bytes): The current value of the processor day counter after the charge
for starting the 24 hour period.
v Word 18 value (second 2 bytes): The current value of the hours remaining in the current period
counter. (This will always be 24 hours.)
Out of compliance due to the expiration of a trial CoD period
An informational log entry is made when the system goes out of compliance due to either:
1. The expiration of a trial CoD period.
2. The cancellation of a trial CoD period.
v Word 16 value (first 2 bytes): 0900
v Word 17 value (first 2 bytes): The number of trial on/off CoD resources out of compliance.
v Word 17 value (second 2 bytes): The new number of trial on/off CoD resources. This value is
always 0.
v Word 18 value (first 2 bytes): The current value of the processor day counter.
v Word 18 value (second 2 bytes): The current value of the hours remaining in the current period
counter.
Out of compliance due to the expiration of an on/off CoD period
An informational log entry is made when the system goes out of compliance due to the expiration
of an on/off CoD period (when the processor day counter is fully decremented to zero).
v Word 16 value (first 2 bytes): 0A00
v Word 17 value (first 2 bytes): The number of on/off CoD resources out of compliance.
v Word 17 value (second 2 bytes): The new number of on/off CoD resources. This value is
always 0.
v Word 18 value (first 2 bytes): The current value of the processor day counter. This value is
always 0.
v Word 18 value (second 2 bytes): The current value of the hours remaining in the current period
counter. This value is always 0.
Trial CoD termination
An informational log entry is made each time a trial CoD period times out.
v Word 16 value (first 2 bytes): 0B00
v Word 17 value (first 2 bytes): The number of processors originally requested.
v Word 17 value (second 2 bytes): This value is not used; it will be 0.
v Word 18 value (first 2 bytes): The current value of the processor day counter.
v Word 18 value (second 2 bytes): The current value of the hours remaining in the current period
counter.
SPCN Informational Codes
The following values of word 13 indicate an SPCN informational message: C006, C007, C00C, C030,
C0E0, C0E2, C0F0, C0F1. No action is required by the customer or service representative.