To enable or disable runtime recoverable error repeat gard, use option 78 of the Memory
Configuration/Deconfiguration Menu. The default is enabled.
The failure history of each book is retained. If a book with a history of failures is brought back online by
disabling Repeat Gard, it remains online if it passes testing during the boot process. However, if Repeat
Gard is enabled, the book is taken offline again because of its history of failures.
The four inner memory books, if present, are listed first, followed by the four outer books, if present.
The memory books are shown in the following order of physical location code:
1
U1.18-P1-M2
2
U1.18-P1-M3
3
U1.18-P1-M7
4
U1.18-P1-M6
v Power Control Network Utilities Menu
POWER CONTROL NETWORK UTILITIES MENU
1. Lamp Test for all Operator Panels
2. Display I/O Type
3. Change I/O Type
4. Collect & display SPCN trace data
5. Start SPCN Flash Update
6. Display Power Subsystem FRU Code Levels
7. Power Subsystem Code Update via the Power Control Network
Currently Enabled
8. Start Power Subsystem Code Update
98. Return to Previous Menu
0>
– Lamp Test for All Operator Panels
Selecting this option tests the media drawer operator panel's indicators by causing them to blink on
and off for approximately 30 seconds.
– Display I/O Type
This option, when selected, will display the SPCN address of the CEC drawer (D0), and the I/O type
of the service processor (which is part of the primary I/O book assembly).
– Change I/O Type
Use this option to change the I/O type of the primary I/O book after a service action or configuration
change if the I/O type is incorrect. If this option is chosen, you will be asked to make the following
entries:
- For the I/O drawer address, type 1.
- For the I/O type, type:
- If a High Performance Switch (machine type 7045-SW4) is installed in or attached to the system,
type 9D.
- If a High Performance Switch (machine type 7045-SW4) is not installed in or attached to the
system, type 98.
If either value is not valid, a failure message displays on the console. Press Enter to return to the
Power Control Network Utilities Menu.
– Collect & display SPCN trace data
5
U1.18-P1-M4
6
U1.18-P1-M8
7
U1.18-P1-M5
8
U1.18-P1-M1
Chapter 7. Using the Service Processor
799