Error Code Description
460B 527A CUoD capacity card fault
460B 527C CUoD capacity card fault
460C 248B I/O subsystem and IPL detected fault in
operator panel
460C 25C0 I/O subsystem and IPL detected fault in system
backplane
460C 25C1 I/O subsystem and IPL detected fault in 1.0
GHz clock card
460C 25E6 SMA 4-port switch adapter fault
460C 2738 I/O subsystem and IPL detected fault in I/O
book 1, 3, or 4
460C 273C I/O subsystem and IPL detected fault in primary
I/O book - Slot 0
460C 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
460C 273F SMA 2-port switch adapter fault
460C 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460C 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460C 28B0 I/O subsystem and IPL detected fault in I/O
subsystem PCI backplane
Action/
Possible Failing FRU
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
Operator panel
Location: U1.17-L1
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
Replace the I/O book (switch adapter) specified
by the location code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Replace the I/O book (switch adapter) specified
by the location code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
I/O subsystem PCI backplane at location
specified in error code
Chapter 5. Error Code to FRU Index