IBM pSeries 690 Service Manual page 458

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
1017 CDC6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1017 F4x6 Hardware configuration does not support
N-mode power.
1017 F516 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the fourth I/O subsystem,
location: U1.13.
1017 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the fourth I/O subsystem,
location: U1.13.
1017 xx11 Fourth I/O subsystem in primary rack (no IBF),
DCA-1
1017 xx13 Seeprom fault on DCA-1 in fourth I/O subsystem
(no IBF) in primary rack
1017 xx15 Fourth I/O subsystem in primary rack (no IBF)
1017 xx17 Problem with fan 1 and fan 3 in fourth I/O
subsystem (no IBF installed) in primary rack
1017 xx21 Fourth I/O subsystem in primary rack (no IBF),
DCA-2
1017 xx23 Seeprom fault on DCA-2 in fourth I/O subsystem
(no IBF) in primary rack
442
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1520: Power" on page 194.
Call Service Support
This is normally an informational message. It
should be accompanied by other error codes that
more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
This is normally an informational message. It
should be accompanied by other error codes that
more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
U1.13-V1
U1.13-V1
If there is no DCA in U1.18-P1-V8, go to "MAP
1520: Power" on page 194 with these pairs of
location codes:
1. U1.13-V1/Q1 and U1.35-P2-X3/Q7
2. U1.13-V1/Q2 and U1.35-P1-X3/Q7
If there is a 6th DCA in U1.18-P1-V8, go to
"MAP 1520: Power" on page 194 with these
pairs of location codes:
1. U1.13-V1/Q1 and U1.35-P2-X2/Q9
2. U1.13-V1/Q2 and U1.35-P1-X2/Q9
1. DCA-1
Location U1.13-V1
2. Fan 1,
Location U1.13-F1
3. Fan 3,
Location U1.13-F3
U1.13-V2
U1.13-V2

Advertisement