Step 152l-16
Turn on the power.
Step 152l-17
Did the system stop with the same error code as recorded in "Step 152l-1" on page 295?
Yes
Go to "Step 152l-23."
No
Go to "Step 152l-18."
Step 152l-18
One of the cards just removed is defective.
Turn off the power.
Make sure all the green "power good out" LEDs of both I/O subsystem DCAs are off.
Step 152l-19
Reinsert one of the cards that is removed and listed in "Step 152l-15" on page 296.
Step 152l-20
Turn on the power.
Step 152l-21
Did the system stop with the same error code as recorded in "Step 152l-1" on page 295?
Yes
The card just reinserted is defective. Replace it. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152l-22."
Step 152l-22
Have all the cards listed in "Step 152l-15" on page 296 been reinserted?
Yes
The symptom has changed. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152l-19."
Step 152l-23
Turn off the power.
Examine the green "power good out" LEDs of both I/O subsystem DCAs.
Chapter 3. Maintenance Analysis Procedures
297