Error Code Description
406D 0D04 Attention handler detected fault in L3 cache
module 4
406D 0D05 Attention handler detected fault in L3 cache
module 5
406D 0D06 Attention handler detected fault in L3 cache
module 6
406D 0D07 Attention handler detected fault in L3 cache
module 7
406D 0D08 Attention handler detected fault in L3 cache
module 8
406D 0D09 Attention handler detected fault in L3 cache
module 9
406D 0D0A Attention handler detected fault in L3 cache
module 10
406D 0D0B Attention handler detected fault in L3 cache
module 11
406D 0D0C Attention handler detected fault in L3 cache
module 12
406D 0D0D Attention handler detected fault in L3 cache
module 13
406D 0D0E Attention handler detected fault in L3 cache
module 14
406D 0D0F Attention handler detected fault in L3 cache
module 15
406D 0EA0 Attention handler detected fault in MOPS
service processor code
406D 0EA1 Attention handler detected fault in processor
subsystem code on main processor
406D 0EA2 Attention handler detected fault in PRD code on
service processor
406D 0EA4 The service processor firmware detected a
hardware problem but was unable to isolate the
source.
648
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
L3 cache module 4 and L3 VPD card
Location: U1.18-P1-C8 and U1.18-P1-H2.1
L3 cache module 5 and L3 VPD card
Location: U1.18-P1-C20 and U1.18-P1-H2.1
L3 cache module 6 and L3 VPD card
Location: U1.18-P1-C16 and U1.18-P1-H2.1
L3 cache module 7 and L3 VPD card
Location: U1.18-P1-C12 and U1.18-P1-H2.1
L3 cache module 8 and L3 VPD card
Location: U1.18-P1-C19 and U1.18-P1-H2.1
L3 cache module 9 and L3 VPD card
Location: U1.18-P1-C18 and U1.18-P1-H2.1
L3 cache module 10 and L3 VPD card
Location: U1.18-P1-C14 and U1.18-P1-H2.1
L3 cache module 11 and L3 VPD card
Location: U1.18-P1-C15 and U1.18-P1-H2.1
L3 cache module 12 and L3 VPD card
Location: U1.18-P1-C17 and U1.18-P1-H2.1
L3 cache module 13 and L3 VPD card
Location: U1.18-P1-C5 and U1.18-P1-H2.1
L3 cache module 14 and L3 VPD card
Location: U1.18-P1-C9 and U1.18-P1-H2.1
L3 cache module 15 and L3 VPD card
Location: U1.18-P1-C13 and U1.18-P1-H2.1
1. Access the service processor error log. Find
the error log entry for the 406x 0EA0 error.
Look for a hardware error of the form 450x
yyyy, 460x yyyy, or 4B2x yyyy with a
timestamp within a few minutes of the 406x
0EA0 error. Follow the actions for this
hardware error.
2. If there is no hardware error in the service
processor error log with a timestamp that is
close to the 406x 0EA0 error, or following
the actions for the hardware error does not
resolve the problem, check for platform
firmware updates. If an update is available,
apply it.
3. If a platform firmware update is not
available, or the update does not correct the
problem, call service support.
1. Check for operating system updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
Call service support.