Error Code Description
4B2D 25E5 Processor subsystem detected fault in 4-way
processor MCM
4B2D 25E9 Processor subsystem detected fault in 8-way
processor MCM
4B2D 28B0 Processor subsystem and attention handler
detected fault in I/O subsystem PCI backplane
4B2D 28B1 Processor subsystem and attention handler
detected fault in I/O subsystem DASD
backplane
4B2D 526B Fault detected in 4-way or 8-way CUoD MCM
4B2D 526C Fault detected in 4-way or 8-way CUoD MCM
4B2D 526D Fault detected in 4-way or 8-way CUoD MCM
4B2D 526E Fault detected in 4-way or 8-way CUoD MCM
4B2E 248B Processor subsystem and scan control routines
detected fault in operator panel
4B2E 258A Processor subsystem detected fault in 4-way
processor MCM
4B2E 25C0 Processor subsystem and scan control routines
detected fault in system backplane
4B2E 25C1 Processor subsystem and scan control routines
detected fault in 1.0 GHz clock card
4B2E 25C7 Processor subsystem and scan control routines
detected fault in 4-way processor MCM
4B2E 25C8 Processor subsystem and scan control routines
detected fault in 4-way processor MCM
4B2E 25CF Processor subsystem detected fault in 8-way
processor MCM
4B2E 25D3 Processor subsystem and scan control routines
detected fault in 8-way processor MCM with
VPD card
4B2E 25D5 Processor subsystem and scan control routines
detected fault in 8-way processor MCM with
VPD card (8-, 16-, or 24-way)
4B2E 25D7 Fault in 4-way processor MCM detected
746
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Operator panel
Location: U1.17-L1
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.

Advertisement

Table of Contents
loading

Table of Contents