1015 7017 Problem with fan 3 in second I/O subsystem in
primary rack
1015 7027 Problem with fan 4 in second I/O subsystem in
primary rack
1015 7117 Problem with fan 1 and fan 3 in second I/O
subsystem in primary rack
1015 7127 Problem with fan 2 and fan 4 in second I/O
subsystem in primary rack
1015 8A00 The SPCN firmware has detected a change in
the drawer configuration
1015 B014 Overcurrent or overvoltage problem with 3.3V in
second I/O subsystem
1015 B024 Overcurrent or overvoltage problem with 5.0V in
second I/O subsystem
1015 B034 Overcurrent or overvoltage problem with 2.5V in
second I/O subsystem
1015 B044 Overcurrent or overvoltage problem with 12.0V in
second I/O subsystem
1015 B054 Overcurrent or overvoltage problem with -12.0V
in second I/O subsystem
1015 B814 Overcurrent or overvoltage problem with 3.3V in
second I/O subsystem
1015 B824 Overcurrent or overvoltage problem with 5.0V in
second I/O subsystem
1015 B834 Overcurrent or overvoltage problem with 2.5V in
second I/O subsystem
1015 B844 Overcurrent or overvoltage problem with 12.0V in
second I/O subsystem
1015 B854 Overcurrent or overvoltage problem with -12.0V
in second I/O subsystem
1015 BF06 Unable to resolve the chassis VPD in an I/O
subsystem
432
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. DCA-1
Location: U1.5-V1
2. Fan 3
Location: U1.5-F3
1. DCA-2
Location: U1.5-V2
2. Fan 4
Location: U1.5-F4
1. DCA-1
Location: U1.5-V1
2. Fans 1 and 3
Location: U1.5-F1 and U1.5-F3
1. DCA-2
Location: U1.5-V2
2. Fans 2 and 4
Location: U1.5-F2 and U1.5-F4
Informational message.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
Go to "MAP 1520: Power" on page 194.
The chassis VPD in the I/O subsystem drawer
identified by the location code could not be
resolved. This may be an indication that more
than one FRU in the drawer was replaced during
a service action. If this is the case, reinstall the
original FRUs in the drawer, then replace the
FRUs one at a time.
If only one FRU was replaced and this error
code occurred, call service support.