Error Code Description
406B 0EE1 Wire tests detected fault in service processor
code (invalid MRU to mapping)
406B 0EE2 Wire tests detected fault in service processor
firmware fault
406B 0EE5 Wire tests detected firmware error; no callout
available
406B 25E6 SMA 4-port switch adapter fault
406B 273F SMA 2-port switch adapter fault
406C 0001 IPL detected clock card assembly failure
406C 0002 IPL detected backplane assembly failure
406C 0003 IPL detected fault in MCM module 0
406C 0004 IPL detected fault in MCM module 2
406C 0005 IPL detected fault in MCM module 1
406C 0006 IPL detected fault in MCM module 3
406C 0007 IPL detected fault in L3 VPD card
406C 000A IPL detected fault in primary I/O book 1 (slot 0)
406C 000B IPL detected fault in secondary I/O book (slot 1) Go to "MAP 1540: Problem Isolation
406C 000C IPL detected fault in I/O book 3 (slot 2)
406C 000D IPL detected fault in I/O book 4 (slot 3)
406C 000E CUoD capacity card
406C 0010 IPL detected fault in Memory book (slot 0)
406C 0011 IPL detected fault in Memory book (slot 1)
624
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
Replace the I/O book (switch adapter) specified
by the location code.
Replace the I/O book (switch adapter) specified
by the location code.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
MCM module 0 and VPD card
Location: U1.18-P1-C1 and U1.18-P1-H2.3
MCM module 2 and VPD card
Location: U1.18-P1-C4 and U1.18-P1-H2.4
MCM module 1 and VPD card
Location: U1.18-P1-C3 and U1.18-P1-H2.5
MCM module 3 and VPD card
Location: U1.18-P1-C2 and U1.18-P1-H2.6
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as "new
defective".)
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
Procedures" on page 310.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310.
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
Memory book (slot 0)
Location: U1.18-P1-M2
Memory book (slot 1)
Location: U1.18-P1-M3