Error Code Description
460E 25E6 SMA 4-port switch adapter fault
460E 2738 I/O subsystem and scan control routines
detected fault in I/O book 1, 3, or 4
460E 273C I/O subsystem and scan control routines
detected fault in primary I/O book - Slot 0
460E 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
460E 273F SMA 2-port switch adapter fault
460E 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460E 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460E 28B0 I/O subsystem and scan control routines
detected fault in I/O subsystem PCI backplane
460E 28B1 I/O subsystem and scan control routines
detected fault in I/O subsystem DASD
backplane
460E 525E CUoD capacity card fault
460E 525F CUoD capacity card fault
726
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Replace the I/O book (switch adapter) specified
by the location code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Replace the I/O book (switch adapter) specified
by the location code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.