Step 154A-22
Is the value recorded in "Step 154A-1" on page 363 for word 13 of this error code equal to
0000A218 or 0000A21B?
No
Go to "Step 154A-5" on page 363.
Yes
Go to "Step 154A-23."
Step 154A-23
Replace the following cards and modules, if present, one at a time:
v First location code item recorded, if any, in "Step 154A-1" on page 363.
v Second location code item recorded, if any, in "Step 154A-1" on page 363.
v Primary I/O Book at U1.18-P1-H2 if not recorded in "Step 154A-1" on page 363.
v Component on which you are trying to turn on the identify LED at the location you selected.
Step 154A-24
Turn on the power.
Step 154A-25
Did the system stop with the same error code as recorded in "Step 154A-1" on page 363?
No
The card or module just replaced was defective. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
Yes
Go to "Step 154A-26."
Step 154A-26
Have all the cards or modules listed in "Step 154A-23" been replaced?
No
Go to "Step 154A-2" on page 363.
Yes
Go to "Step 154A-14" on page 365.