Error Code Description
4064 0BFB Processor subsystem tests detected fault in I/O
hub chip 11 (port x)
4064 0BFC Processor subsystem tests detected fault in I/O
hub chip 12 (port x)
4064 0BFD Processor subsystem tests detected fault in I/O
hub chip 13 (port x)
4064 0C03 Processor subsystem tests detected fault in all
MCMs
4064 0C09 Processor subsystem tests detected fault in all
memory books
4064 0C0A Processor subsystem tests detected fault in all
I/O books
4064 0C10 Processor subsystem tests detected mismatch
between MCM 0 and VPD card
4064 0C11 Processor subsystem tests detected mismatch
between MCM 2 and VPD card
4064 0C12 Processor subsystem tests detected mismatch
between MCM 1 and VPD card
4064 0C13 Processor subsystem tests detected mismatch
between MCM 3 and VPD card
4064 0CA5 Processor subsystem tests detected invalid
processor subsystem configuration
4064 0CA6 Processor subsystem tests detected no usable
main storage
4064 0CA9 Processor subsystem tests detected
configuration error with processor memory
4064 0D00 Processor subsystem tests detected fault in L3
cache module 0
4064 0D01 Processor subsystem tests detected fault in L3
cache module 1
4064 0D02 Processor subsystem tests detected fault in L3
cache module 2
4064 0D03 Processor subsystem tests detected fault in L3
cache module 3
528
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H3/Q1
b. U1.18-P1-H3/Q2
2. Replace the RIO book,
Location: U1.18-P1-H3
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q1
b. U1.18-P1-H4/Q2
2. Replace the RIO book,
Location: U1.18-P1-H4.
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q3
b. U1.18-P1-H4/Q4
2. Replace the RIO book,
Location: U1.18-P1-H4
Go to "MAP 1543: MCM Module Problem
Isolation" on page 339.
Go to "MAP 1546: Memory Book Problem
Isolation" on page 347.
Go to "MAP 1547: I/O Book Problem Isolation"
on page 350.
Plugging error with FRU kit
Location: U1.18-P1-C1 and U1.18-P1-H2.3
Plugging error with FRU kit
Location: U1.18-P1-C4 and U1.18-P1-H2.4
Plugging error with FRU kit
Location: U1.18-P1-C3 and U1.18-P1-H2.5
Plugging error with FRU kit
Location: U1.18-P1-C2 and U1.18-P1-H2.6
Verify that MCMs, memory books, and L3
modules are correctly configured.
Reboot the system in slow mode to isolate the
failure.
Reboot the system in slow mode to isolate the
failure.
L3 cache module 0 and L3 VPD card
Location: U1.18-P1-C6 and U1.18-P1-H2.1
L3 cache module 1 and L3 VPD card
Location: U1.18-P1-C7 and U1.18-P1-H2.1
L3 cache module 2 and L3 VPD card
Location: U1.18-P1-C11 and U1.18-P1-H2.1
L3 cache module 3 and L3 VPD card
Location: U1.18-P1-C10 and U1.18-P1-H2.1