Step 1421-6
Is the PCI slot power LED of the location recorded in "Step 1421-3" on page 190 on?
NO
Go to "Step 1421-7."
YES
Go to "Step 1421-12."
Step 1421-7
Are there any empty PCI slots attached to the system that are not assigned to any partitions?
NO
Go to "Step 1421-12."
YES
Go to "Step 1421-8."
Step 1421-8
Assign the available empty and unassigned slot to the partition that will not boot.
Step 1421-9
Insert a new adapter of the same type recorded in "Step 1421-3" on page 190 into the slot assigned in
"Step 1421-8."
Step 1421-10
Move any external cabling from the adapter in the slot recorded in "Step 1421-3" on page 190 to the
adapter in the slot assigned in "Step 1421-8."
Step 1421-11
Attempt to boot the partition.
Does the partition boot?
NO
Go to "Step 1421-12."
YES
Partition and all resources are operational. Schedule repair for the slot recorded in "Step 1421-3"
on page 190 with the customer. Go to "MAP 0410: Repair Checkout" in the RS/6000 and
Eserver pSeries Diagnostic Information for Multiple Bus Systems. This ends the procedure.
Step 1421-12
Cannot isolate the adapter without powering off the entire system. Schedule repair for the slot recorded in
"Step 1421-3" on page 190 with the customer. This ends the procedure.
MAP 1422: Slot is Empty Even When Populated
Step 1422-1
Record the I/O drawer and slot location of the slot that is populated with an adapter but shows empty in
the PCI hot-plug manager. Also record the adapter type.