Error Code Description
406B 0B03 Wire tests detected fault in I/O book (slot 0 RIO
port 3)
406B 0B10 Processor subsystem tests detected fault in SNI
adapter
406B 0B11 Processor subsystem tests detected fault in SNI
adapter
406B 0B12 Processor subsystem tests detected fault in SNI
adapter
406B 0B13 Processor subsystem tests detected fault in SNI
adapter
406B 0B20 Wire tests detected fault in I/O book
406B 0B21 Wire tests detected fault in I/O book
616
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Check the I/O cabling between the primary
I/O book and the I/O subsystems.
3. Primary I/O book
Location: U1.18-P1-H2
4. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the SNI adapter
book and the High Performance Switch.
3. SNI adapter book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the SNI adapter
book and the High Performance Switch.
3. SNI adapter book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the SNI adapter
book and the High Performance Switch.
3. SNI adapter book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the SNI adapter
book and the High Performance Switch.
3. SNI adapter book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H3
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H3
4. Call service support.