Table 2. Firmware Checkpoints (continued)
Checkpoint
E588
E589
E58A
E58B
E58C
E58D
Description
Set up EADS function registers
Set up EADS function
Set up EADS function registers
Set up EADS function registers
Set up EADS function registers
Set up EADS function registers
Action/
Possible Failing FRU
1. Replace the I/O cable specified by the
location code.
2. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
3. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
1. Replace the I/O cable specified by the
location code.
2. Replace the I/O subsystem backplane
that the I/O cable in step 1 is attached
to.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
Chapter 4. Checkpoints
403