IBM pSeries 690 Service Manual page 712

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
4506 307E Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
4506 308A Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4506 308B Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4506 308C Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4506 308D Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
45064 308E Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
4506 30BD Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
inner memory book
4506 30C3 Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
inner memory book
4506 30C6 Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
outer memory book
4506 30CC Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
outer memory book
4507 248B Memory subsystem and bus tests detected fault
in operator panel
4507 25C0 Memory subsystem and bus tests detected fault
in system backplane
4507 25C1 Memory subsystem and bus tests detected fault
in 1.0 GHz clock card
4507 25D9 Memory subsystem and bus tests detected fault
in L3 VPD card used with 1.1 GHz MCM and
1.3 GHz MCM
4507 25E7 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4507 25E8 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4507 25F1 Memory subsystem and bus tests detected fault
in L3 VPD card used with 1.3 GHz MCM
4507 25F9 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4507 269A Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
4507 28B0 Memory subsystem and bus tests detected fault
in I/O subsystem PCI backplane
4507 28B1 Memory subsystem and bus tests detected fault
in I/O subsystem DASD backplane
696
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 342.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 342.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 342.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Operator panel
Location: U1.17-L1
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code

Advertisement

Table of Contents
loading

Table of Contents