Error Code Description
450D 25C0 Memory subsystem and attention handler
detected fault in system backplane
450D 25C1 Memory subsystem and attention handler
detected fault in 1.0 GHz clock card
450D 25D9 Memory subsystem and attention handler
detected fault in L3 VPD card used with 1.1
GHz MCM and 1.3 GHz MCM
450D 25E7 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
450D 25E8 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
450D 25F1 Memory subsystem and attention handler
detected fault in L3 VPD card used with 1.3
GHz MCM
450D 25F9 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
450D 269A Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
450D 28B0 Memory subsystem and attention handler
detected fault in I/O subsystem PCI backplane
450D 28B1 Memory subsystem and attention handler
detected fault in I/O subsystem DASD
backplane
450D 302A Memory subsystem and attention handler
detected fault in 8 GB memory book (inner)
450D 302B Memory subsystem and attention handler
detected fault in 8 GB memory book (outer)
450D 302C Memory subsystem and attention handler
detected fault in 32 GB memory book (inner)
450D 302D Memory subsystem and attention handler
detected fault in 32 GB memory book (outer)
450D 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
450D 305B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
450D 305C Memory subsystem and attention handler
detected fault in 4 GB inner memory book
450D 305D Memory subsystem and attention handler
detected fault in 4 GB outer memory book
450D 305E Memory subsystem and attention handler
detected fault in 16 GB inner memory book
450D 305F Memory subsystem and attention handler
detected fault in 16 GB outer memory book
Action/
Possible Failing FRU
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 352.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 310 to isolate the failing
component.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 342.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 342.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 342.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 344.
Chapter 5. Error Code to FRU Index
707

Advertisement