Error Code Description
1021 F516 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the first I/O subsystem in the
secondary rack, location: U2.1.
1021 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the first I/O subsystem in the
secondary rack, location: U2.1.
1021 xx11 First I/O subsystem in second rack, DCA-1
1021 xx13 Seeprom fault on DCA-1 in first I/O subsystem
secondary rack
1021 xx15 First I/O subsystem in second rack, DCA-1,
cable fault
1021 xx17 Problem with fan 1 and fan 3 in first I/O
subsystem in second rack
1021 xx21 First I/O subsystem in second rack, DCA-2
1021 xx23 Seeprom fault on DCA-2 in first I/O subsystem
secondary rack
1021 xx25 First I/O subsystem in second rack, DCA-2,
cable fault
1021 xx27 Problem with fan 2 and fan 4 in first I/O
subsystem in second rack
1021 xx31 First I/O subsystem in secondary rack I/O
subsystem backplane 1 fault
1021 xx33 Seeprom fault on I/O subsystem backplane 1 in
first I/O subsystem in secondary rack
1021 xx41 First I/O subsystem in secondary rack I/O
subsystem backplane 2 fault
Action/
Possible Failing FRU
This is normally an informational message. It
should be accompanied by other error codes that
more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
This is normally an informational message. It
should be accompanied by other error codes that
more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
U2.1-V1
U2.1-V1
Go to "MAP 1520: Power" on page 194 with
these pairs of location codes:
1. U2.1-V1/Q1 and U1.35-P2-X2/Q1
2. U2.1-V1/Q2 and U1.35-P1-X2/Q1
1. DCA-1
Location U2.1–V1
2. Fan 1,
Location U2.1–F1
3. Fan 3,
Location U2.1–F3
U2.1-V2
U2.1-V2
Go to "MAP 1520: Power" on page 194 with
these pairs of location codes:
1. U2.1-V2/Q1 and U1.35-P2-X2/Q2
2. U2.1-V2/Q2 and U1.35-P1-X2/Q2
1. DCA-2
Location U2.1–V2
2. Fan 2,
Location U2.1–F2
3. Fan 4,
Location U2.1–F4
U2.1-P1
U2.1-P1
U2.1-P2
Chapter 5. Error Code to FRU Index
469