Error Code Description
406D 0B36 Error code generation/logging detected fault in
I/O book or SNI adapter
406D 0B37 Error code generation/logging detected fault in
I/O book or SNI adapter
406D 0BF0 Attention handler detected fault in I/O hub chip
0 (port x)
406D 0BF1 Attention handler detected fault in I/O hub chip
1 (port x)
406D 0BF2 Attention handler detected fault in I/O hub chip
2 (port x)
406D 0BF3 Attention handler detected fault in I/O hub chip
3 (port x)
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Check the I/O cabling between the third I/O
book and the I/O subsystems, or the SNI
adapter and the High Performance Switch,
depending on which adapter is installed in
location U1.18-P1-H4.
3. Third I/O book or SNI adapter
Location: U1.18-P1-H4
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the third I/O
book and the I/O subsystems, or the SNI
adapter and the High Performance Switch,
depending on which adapter is installed in
location U1.18-P1-H4.
3. Third I/O book or SNI adapter
Location: U1.18-P1-H4
4. Call service support.
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H2/Q1
b. U1.18-P1-H2/Q2
2. Replace the primary I/O book,
Location: U1.18-P1-H2
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H2/Q3
b. U1.18-P1-H2/Q4
2. Replace the primary I/O book,
Location: U1.18-P1-H2
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H1/Q3
b. U1.18-P1-H1/Q4
2. Replace the RIO book,
Location: U1.18-P1-H1
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H1/Q1
b. U1.18-P1-H1/Q2
2. Replace the RIO book,
Location: U1.18-P1-H1