show facility-alarm relay

show facility-alarm relay
Use the show facility-alarm relay user EXEC command to display facility alarms associated with the
indicated relay circuitry.
Syntax Description
major
minor
| begin
| exclude
| include
expression
Command Modes
User EXEC
Command History
Release
12.1(12c)EA1
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show facility-alarm relay minor command. It displays alarm
information for the minor relays.
Switch> show facility-alarm relay minor
Source
Switch
Related Commands
Command
alarm facility power-supply
alarm facility temperature
alarm profile (global
configuration)
show facility-alarm status
Catalyst 2950 and Catalyst 2955 Switch Command Reference
A-18
show facility-alarm relay {major | minor} [ | {begin | exclude | include} expression]
Display alarms associated with major relay.
Display alarms associated with minor relay.
(Optional) Display begins with the line that matches the expression.
(Optional) Display excludes lines that match the expression.
(Optional) Display includes lines that match the specified expression.
Expression in the output to use as a reference point.
Modification
This command was introduced.
Description
1 Temp above secondary thresh
Description
Sets power supply alarm options.
Sets temperature alarm options.
Creates alarm profiles with alarm IDs and alarm options to be
attached to interfaces.
Display alarms generated on the switch.
Appendix A
Catalyst 2955 Alarm Commands
Relay
Time
MIN
Mar 01 1993 00:0 1:17
OL-10102-01