Appendix A
Catalyst 2955 Alarm Commands
Examples
This example shows how to set the secondary temperature with a high threshold value of 45
alarms and how to send traps to the minor relay circuitry, to the syslog, and to an SNMP server:
Switch(config)# alarm facility temperature secondary 45
Switch(config)# alarm facility temperature secondary relay minor
Switch(config)# alarm facility temperature secondary syslog
Switch(config)# alarm facility temperature secondary notifies
This example shows how to disable the secondary temperature alarm:
Switch(config)# no alarm facility temperature secondary 45
This example shows how to set the primary temperature alarm with alarms and traps to go to the syslog
and to the major relay circuitry:
Switch(config)# alarm facility temperature primary syslog
Switch(config)# alarm facility temperature primary relay major
Related Commands
Command
show alarm settings
snmp-server enable traps
OL-10102-01
Description
Displays environmental alarm settings and options.
Enables the switch to send SNMP notification for various trap types to
the network management system (NMS).
Catalyst 2950 and Catalyst 2955 Switch Command Reference
alarm facility temperature