show facility-alarm status

Use the show facility-alarm status user EXEC command to display all generated alarms for the switch.
Syntax Description
critical
info
major
minor
| begin
| exclude
| include
expression
Command Modes
User EXEC
Command History
Release
12.1(12c)EA1
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show facility-alarm status command. It displays alarm
information for the switch.
Switch> show facility-alarm status
Source
FastEthernet0/3
1993 00:02:22
Related Commands
Command
alarm facility power-supply
alarm facility temperature
alarm profile (global
configuration)
show facility-alarm relay
OL-10102-01
show facility-alarm status [critical | info | major | minor] [ | {begin | exclude | include}
expression]
(Optional) Display only critical facility alarms.
(Optional) Display all facility alarms.
(Optional) Display major facility alarms and higher.
(Optional) Display major facility alarms and higher.
(Optional) Display begins with the line that matches the expression.
(Optional) Display excludes lines that match the expression.
(Optional) Display includes lines that match the specified expression.
Expression in the output to use as a reference point.
Modification
This command was introduced.
Severity Description
MINOR
2 Port Not Forwarding
Description
Sets power supply alarm options.
Sets temperature alarm options.
Creates alarm profiles with alarm IDs and alarm options to be
attached to interfaces.
Displays alarm relays generated on the switch.
Catalyst 2950 and Catalyst 2955 Switch Command Reference
show facility-alarm status
Relay
Time
NONE