Show Storm-Control - Cisco Catalyst 2950 Command Reference Manual

Hide thumbs Also See for Catalyst 2950:
Table of Contents

Advertisement

Chapter 2
Catalyst 2950 and 2955 Cisco IOS Commands

show storm-control

Use the show storm-control user EXEC command to display the packet-storm control information. This
command also displays the action that the switch takes when the thresholds are reached.
Syntax Description
interface-id
broadcast
history
multicast
unicast
| begin
| exclude
| include
expression
Command Modes
User EXEC
Command History
Release
12.1(6)EA2
Usage Guidelines
If the variable interface-id is omitted, the show storm-control command displays storm-control settings
for all ports on the switch.
You can display broadcast, multicast, or unicast packet-storm information by using the corresponding
keyword. When no option is specified, the default is to display broadcast storm-control information.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show storm-control broadcast command when the rising and
falling suppression levels are defined as percentages of the total bandwidth:
Switch> show storm-control broadcast
Interface
---------
Fa0/1
Fa0/2
Fa0/3
Fa0/4
0L-10102-01
show storm-control [interface-id] [{broadcast | history | multicast | unicast}] [ | {begin | exclude
| include} expression]
(Optional) Port for which information is to be displayed.
(Optional) Display broadcast storm information.
(Optional) Display storm history on a per-port basis.
(Optional) Display multicast storm information.
(Optional) Display unicast storm information.
(Optional) Display begins with the line that matches the specified
expression.
(Optional) Display excludes lines that match the specified expression.
(Optional) Display includes lines that match the specified expression.
Expression in the output to use as a reference point.
Modification
This command was introduced. It replaced the show port storm-control
command.
Filter State
Trap State
-------------
-------------
<inactive>
<inactive>
<inactive>
<inactive>
<inactive>
<inactive>
Forwarding
Below rising
Upper
Lower
Current
-------
-------
-------
100.00%
100.00%
100.00%
100.00%
100.00%
100.00%
30.00%
20.00% 20.32%
Catalyst 2950 and Catalyst 2955 Switch Command Reference
show storm-control
Traps Sent
----------
0.00%
0
0.00%
0
0.00%
0
17
2-407

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2955

Table of Contents