System Options - Paradyne 8779 User Manual

Tdm sdsl termination units
Table of Contents

Advertisement

System Options

For System Options, refer to
Options screen, follow this menu selection sequence:
Table A-7. System Options (1 of 2)
8700-A2-GB20-40
Main Menu
Configuration
main/config/system
Slot: 18
DSL Mode:
Test Timeout:
Test Duration (min):
Telco Initiated Loopbacks:
Remote Telco Line Loopback:
G.703 Line Termination
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu
Save
DSL Mode
Possible Settings: LTU, NTU
Default Setting: LTU
Controls whether the unit is configured as a control unit or tributary unit.
LTU – The unit is configured as a control unit (Line Termination Unit).
NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.
NOTE: Changing this option will reset the card.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is remotely
managed, so that control can be regained after a test is accidentally executed.
Enable – Loopback and pattern tests end when test duration is reached.
Disable – Tests run until manually terminated from the Network Tests screen or remotely
(network initiated tests). Refer to
May 2002
Table A-7, System
Options. To access the System
Current Configuration
SYSTEM OPTIONS
LTU
Enable
10
Enable
Disabled
120 Ohm
Running Network Tests
in Chapter 8, Testing .
A. Configuration Options
System Options
Model: 87xx
(Model 8777)
(Model 8777)
(Model 8779)
MainMenu
Exit
A-13

Advertisement

Table of Contents
loading