Paradyne 8779 User Manual page 58

Tdm sdsl termination units
Table of Contents

Advertisement

7. Monitoring and Troubleshooting
Table 7-1.
7-6
Health and Status Messages (4 of 4)
Message
What Message Indicates
Primary Clock Failed,
A failure has occurred in the
Pt n
primary clock source for the
DSX-1 or G.703 port.
Primary System Clock
A failure has occurred in the
Failed
clock common to all
cross-connect circuitry.
RAI at G.703,
An RAI (Remote Alarm
Pt n
Indication) signal is being
received by the G.703
interface.
Secondary System
A failure has occurred in the
Clock Failed
fallback clock for the system
clock.
System Operational
There are no problems
detected.
Yellow Alarm at
A Yellow Alarm Indication
DSX-1, Pt n
signal is being received by
the DSX-1 interface.
May 2002
What To Do
1. Verify that the network cable
is securely attached at both
ends.
2. Verify the clock configuration
on the unit and attached
equipment.
3. Contact network provider.
Contact your service
representative.
1. Check the status of the
attached device.
2. Verify that the Line Coding,
Line Framing, and Time Slot
16 configuration options
selected are compatible with
the connected G.703
equipment's configurations.
See
G.703 Interface Options
(Model 8779)
in Appendix A,
Configuration Options .
Contact your service
representative.
No action is needed.
1. Verify that the unit's line
framing and line coding are
compatible.
2. Contact network provider.
8700-A2-GB20-40